| DSP80-180WR | DSP250-60WR | DSP350-42WR | DSP500-30WR | DSP650-23WR | |
| 输出电压 | |||||
| 额定值(V1) | 0~80V | 0~250V | 0~350V | 0~500V | 0~650V | 
| 可设定范围(*9) | 0~84V | 0~262.5V | 0~367.5V | 0~525V | 0~682.5V | 
| 过压保护 (OVP) | 额定输出电压的 0% ~ 110% | ||||
| 电压@额定电流(V2)(速查表) | 27.78V | 83.33V | 119.05V | 166.67V | 217.39V | 
| 编程分辨率 | 5位数 | ||||
| 编程精度(*2) | ± 0.1% 额定电压 | ||||
| 仪表分辨率 | 5位数 | ||||
| 仪表精度(*2) | ± 0.1% 额定电压 | ||||
| 线规(*6) | ± 0.02% 额定电压 | ||||
| 负载调整率(*7) | ± 0.05% 额定电压 | ||||
| 设定值的温度系数 | 100ppm/°C 额定输出电压,预热 30 分钟后 | ||||
| 纹波和噪声 (rms) (*3)(*4) | < 180mVpp < 15mVrms | < 270mVpp < 36mVrms | < 288mVpp < 50mVrms | < 315mVpp < 63mVrms | < 720mVpp < 180mVrms | 
| 满载 | <30ms | ||||
| 满载下来 | <80ms | ||||
| 无负载 | <5s | <10s | <10s | <5s | <6s | 
| 瞬态响应(*5) | < 1.5 毫秒 | ||||
| 远程补偿 | 5V | ||||
| 输出电流 | |||||
| 额定值(A1) | 0~180A | 0~60A | 0~42A | 0~30A | 0~23A | 
| 可设定范围(*10) | 0~189A | 0~63A | 0~44.1A | 0~31.5A | 0~24.15A | 
| 过流保护 (OCP) | 0% ~ 110% 额定输出电流 | ||||
| 电流@额定电压(A2)(速查表) | 62.5A | 20A | 14.28A | 10A | 7.69A | 
| 编程分辨率 | 5位数 | ||||
| 编程精度(*2) | ± 0.2% 额定电流 | ||||
| 仪表分辨率 | 5位数 | ||||
| 仪表精度(*2) | ± 0.2% 额定电流 | ||||
| 线规(*6) | ± 0.05% 额定电流 | ||||
| 负载调整率(*7) | ± 0.15% 额定电流 | ||||
| 设定值的温度系数 | 100ppm/°C 额定输出电压,预热 30 分钟后 | ||||
| 纹波和噪声 (rms)(*3)(*4) | 72mA | 19mA | 16mA | 15mA | 15mA | 
| 输出功率 | |||||
| 额定值 | 0~5kW | ||||
| 可设定范围(*9) | 0~5100W | ||||
| 过功率保护 (OPP) | 0% ~ 110% 额定输出功率 | ||||
| 编程分辨率 | 5位数 | ||||
| 编程精度(*2) | < 额定输出功率的 1% | ||||
| 仪表分辨率 | 5位数 | ||||
| 仪表精度(*2) | ± 0.5% 额定输出功率 | ||||
| 线规(*6) | < 0.05% 额定输出功率 | ||||
| 负载调整率(*7) | < 0.75% 额定输出功率 | ||||
| 内阻 | |||||
| 调整范围 | 0~0.4444Ω | 0~4.1667Ω | 0~8.3333Ω | 0~16.667Ω | 0~28.261Ω | 
| 编程分辨率 | 0.0001Ω | 0.0001Ω | 0.0001Ω | 0.001Ω | 0.001Ω | 
| 编程精度 (*2) | <=最大值的 2.3% 反抗 | ||||
| 绝缘 | |||||
| 初级 - 底盘 | 2.5 kV 直流 | ||||
| 小学 - 中学 | 2.5 kV 直流 | ||||
| 次要 - 底盘 | 750VDC | 750VDC | 750VDC | 1000VDC | 1500VDC | 
| 操作环境 | 室内使用 | ||||
| 工作温度 | 0℃~50℃ | ||||
| 工作湿度 | 30%rh ~ 80%rh(不结露) 30℃时最大80%RH,40℃时线性下降至50%RH | ||||
| 贮存温度 | -20℃ ~ 70℃ | ||||
| 储存湿度 | 10%rh ~ 80%rh(无凝露) | ||||
| 高度 | 高达 2000m | ||||
| 冷却方式 | 使用调速风扇强制风冷 | ||||
| 接地极性 | 可接负极接地或正极接地 | ||||
| 输入 | |||||
| 标称输入额定值 | 200V ~ 415V 50Hz/60Hz 三相三线,可选480V 50/60Hz 三相四线 | ||||
| 输入电压范围 | 180VAC ~ 460VAC , 可选 480VAC (type:432VAC ~ 528VAC) | ||||
| 输入频率范围 | 47Hz~63Hz | ||||
| 电流(最大) | 20A/相(输入三相180V) | ||||
| 浪涌电流(最大) | 33A/相(输入三相460V) | ||||
| 输入功率(最大) | 6kVA | 6kVA | 6kVA | 6kVA | 6kVA | 
| 效率 | 86 ~ 95% 因型号而异(*1) | ||||
| 功率因数 | 0.99 typ.(480V 输入) / 0.95 typ.(200 ~ 415V 输入) | ||||
| 漏电流 | < 3.5 毫安 | ||||
| 记忆与序列 | |||||
| 内存数 | 3套(前面板操作) | ||||
| 最大步数 | 每个序列 500 步 | ||||
| 最大序列号 | 16 | ||||
| 步进时间可设定范围 | 0.001 秒 ~ 999999.999 秒 | ||||
| 标准接口 | |||||
| 1 x LXI 1.4 用于通信, | |||||
| J1(辅助控制) | 功能:互锁、外部输出开/关、关断、报警信号输出、输出电压下降信号 | ||||
| 可选模拟编程接口 | |||||
| 状态输出(干接点) | CV 状态、CC 状态、CP 状态、CR 状态、ON/OFF 状态 | ||||
| 电压控制 | 0V~5V或0V~10V范围内额定输出电压的0%~100% | ||||
| 电压控制精度(*2) | +/-0.2% | ||||
| 电流控制 | 0V~5V或0V~10V范围内额定输出电流的0%~100% | ||||
| 电流控制精度(*2) | +/-0.2% | ||||
| 功率控制 | 0V~5V或0V~10V范围内额定输出电流的0%~100% | ||||
| 功率控制精度(*2) | +/-0.2% | ||||
| 监控输出 | 0 ~ 5V 或 0 ~ 10V 输出用于监控 V/A/W | ||||
| 监控精度 (*2) | +/-0.2% | ||||
| 参考输出 | 0 ~ 5VDC 或 0 ~ 10VDC (max=5mA),可在 MENU 中选择。 | ||||
| 可选的 RS-485 编程接口 | |||||
| 波特率 | 4800/9600/19200/38400/57600/115200 | ||||
| 行结束符 | Cr , Lf , Cr+Lf 可选 | ||||
| 可选的 GPIB 编程接口 | |||||
| IEEE 标准 488.2.1992 | |||||
| 尺寸和重量 | |||||
| 外壳(宽x高x深) | 440 x 129 x 660 毫米 | ||||
| 总计(宽x高x深) | 482 x 132 x 765.1 毫米 | ||||
| 重量(公斤) | 27.5 | 26 | 26 | 26 | 26 | 
| DSP80-180WR | DSP250-60WR | DSP350-42WR | DSP500-30WR | DSP650-23WR | |
| *1) 以上数据测试环境:恒温后湿机内,温度0℃~50℃,80%RH,启动30分钟,以2%~100%旅游输出电压、1%~100%焊接输出电流, 回授证明点为输出端子,于输出端子测得之平均数据 | 
| *2)合理度项目于室温23℃±5℃测得 | 
| *3)纹波和噪声(rms 值)测量带宽高达 300 kHz | 
| *4)纹波和噪声(峰值)测量带宽高达 20 MHz | 
| *5)输出电压达到定值±1%时间(输出电压输出值的10%到90%,以搜索性负载连接,输出输出功率10%以上)(图1) | 
| *6)负载负载(1 ~ 100%),输入电压180 ~ 264VAC 或 342 ~ 460VAC | 
| *7) CV: 输入电压,电流变化幅度% ~ 90% CC: 输入电压,电压外景值10% ~ 90% CP: 输入电压,电压电压*电流变化值值 10% ~ 90% | 
| *8)输出响应上升时间:电压由电压值10%上升时间90%图需要时间 输出响应下降时间:电压由电压值90%下降至10%需要时间(2) | 
| *9) WR系列最高输出电压为DSP-WR系列最高输出电压为DSP-WR系列最高输出电压为DSP的105%,但总输出功率不可超过功率的102%,此规格电压线路证明为目的,不可考虑使用,且规格特性不在保证范围内。 | 
| *10) DSP-WR系列最大输出电流为电流的102%,但总输出功率不可比功率的102%,此超出规格的电流以线路证明为目的规格,不可考虑使用,且且特性特性不在保证范围内。 | 
| *11)电源供应器输出特性受线路影响等因素影响,多台系统的精确参数请与本公司联系。 | 
| *12) V1 x A1 ~ V2 x A2 间数值 V 及 A 乘积小于或等于最大功率数值,为宽范围功能可能实现的全部电压和电流组合。 | 
| *13) V1可设定最大电流值为A1,A2可设定最大电压值为V2,V1及A2不同时存在 | 
| *14) LXI介面反应时间:100/1000M网路连线,电脑直接连接至DSP-WR,封包发送完毕后,至DA开始动作时间间隔。 | 
| *15)因本公司不断更新产品,故规格若有变更,恕不另行通知,网页内容说明参考,具体规格依产品时书具体规定。 | 
| *16)擎宏电子保留迳行更动规范及其他产品信息的权利,并拥有对规范的最终能力,且不承担内容之错误或疏失。 | 
| 图1 | 图2 | 
|  | 
 | 
| 10kW规格表: | 10kW型 | ||||
| DSP80-360WR | DSP160-180WR | DSP250-120WR | DSP350-84WR | DSP500-60WR | DSP650-46WR | DSP1000-30WR | DSP-1300-23WR | |
| 输出电压 | ||||||||
| 额定值(V1) | 0~80V | 0~160V | 0~250V | 0~350V | 0~500V | 0~650V | 0~1000V | 0~1300V | 
| 可设定范围(*9) | 0~84V | 0~168V | 0~262.5V | 0~367.5V | 0~525V | 0~682.5V | 0~1050V | 0~1365V | 
| 过压保护 (OVP) | 额定输出电压的 0% ~ 110% | |||||||
| 电压@额定电流(V2)(速查表) | 27.78V | 55.55V | 83.33V | 119.05V | 166.67V | 217.39V | 333.33V | 434.78V | 
| 编程分辨率 | 5位数 | |||||||
| 编程精度(*2) | ± 0.1% 额定电压 | |||||||
| 仪表分辨率 | 5位数 | |||||||
| 仪表精度(*2) | ± 0.1% 额定电压 | |||||||
| 线规(*6) | ± 0.02% 额定电压 | |||||||
| 负载调整率(*7) | ± 0.05% 额定电压 | |||||||
| 设定值的温度系数 | 100ppm/°C 额定输出电压,预热 30 分钟后 | |||||||
| 纹波和噪声 (rms) (*3)(*4) | < 288mVpp < 23mVrms | < 432mVpp < 35mVrms | < 270mVpp < 36mVrms | < 288mVpp < 50mVrms | < 315mVpp <63mVrms | < 720mVpp < 180mVrms | < 1440mVpp < 315mVrms | <2240mVpp < 490mVrms | 
| 满载 | <30ms | |||||||
| 满载下来 | <80ms | |||||||
| 无负载 | <5s | <5s | <10s | <10s | <5s | <6s | <5s | <6s | 
| 瞬态响应(*5) | < 1.5 毫秒 | |||||||
| 远程补偿 | 5V | |||||||
| 输出电流 | ||||||||
| 额定值(A1) | 0~360A | 0~180A | 0~120A | 0~84A | 0~60A | 0~46A | 0~30A | 0~23A | 
| 可设定范围(*10) | 0~378A | 0~189A | 0~126A | 0~88.2A | 0~63A | 0~48.3A | 0~31.5A | 0~24.15A | 
| 过流保护 (OCP) | 0% ~ 110% 额定输出电流 | |||||||
| 电流@额定电压(A2)(速查表) | 125A | 62.5A | 40A | 28.56A | 20A | 15.38A | 10A | 7.69A | 
| 编程分辨率 | 5位数 | |||||||
| 编程精度(*2) | ± 0.2% 额定电流 | |||||||
| 仪表分辨率 | 5位数 | |||||||
| 仪表精度(*2) | ± 0.2% 额定电流 | |||||||
| 线规(*6) | ± 0.05% 额定电流 | |||||||
| 负载调整率(*7) | ± 0.15% 额定电流 | |||||||
| 设定值的温度系数 | 100ppm/°C 额定输出电压,预热 30 分钟后 | |||||||
| 纹波和噪声 (rms)(*3)(*4) | 144mA | 72mA | 38mA | 32mA | 29mA | 29mA | 20mA | 20mA | 
| 输出功率 | ||||||||
| 额定值 | 0~10kW | |||||||
| 可设定范围 | 0~10200W | |||||||
| 过功率保护 (OPP) | 0% ~ 110% 额定输出功率 | |||||||
| 编程分辨率 | 5位数 | |||||||
| 编程精度(*2) | < 额定输出功率的 1% | |||||||
| 仪表分辨率 | 5位数 | |||||||
| 仪表精度(*2) | ± 0.5% 额定输出功率 | |||||||
| 线规(*6) | < 0.05% 额定输出功率 | |||||||
| 负载调整率(*7) | < 0.75% 额定输出功率 | |||||||
| 内阻 | ||||||||
| 调整范围 | 0~0.2222Ω | 0~0.8888Ω | 0~2.0833Ω | 0~4.1667Ω | 0~8.3333Ω | 0~14.130Ω | 0~33.333Ω | 0~56.521Ω | 
| 编程分辨率 | 0.0001Ω | 0.0001Ω | 0.0001Ω | 0.0001Ω | 0.0001Ω | 0.001Ω | 0.001Ω | 0.001Ω | 
| 编程精度 (*2) | <=最大值的 2.3% 反抗 | |||||||
| 绝缘 | ||||||||
| 初级 - 底盘 | 2.5 kV 直流 | |||||||
| 小学 - 中学 | 2.5 kV 直流 | |||||||
| 次要 - 底盘 | 750VDC | 750VDC | 750VDC | 750VDC | 1000VDC | 1500VDC | 1500VDC | 2000VDC | 
| 操作环境 | 室内使用 | |||||||
| 工作温度 | 0℃~50℃ | |||||||
| 工作湿度 | 30%rh ~ 80%rh(不结露) 30℃时最大80%RH,40℃时线性下降至50%RH | |||||||
| 贮存温度 | -20℃ ~ 70℃ | |||||||
| 储存湿度 | 10%rh ~ 80%rh(无凝露) | |||||||
| 高度 | 高达 2000m | |||||||
| 冷却方式 | 使用调速风扇强制风冷 | |||||||
| 接地极性 | 可接负极接地或正极接地 | |||||||
| 输入 | ||||||||
| 标称输入额定值 | 200V ~ 415V 50Hz/60Hz 三相三线,可选480V 50/60Hz 三相四线 | |||||||
| 输入电压范围 | 180VAC ~ 460VAC , 可选 480VAC (type:432VAC ~ 528VAC) | |||||||
| 输入频率范围 | 47Hz~63Hz | |||||||
| 电流(最大) | 40A/Phas(输入三相180V) | |||||||
| 浪涌电流(最大) | 66A/Phas(输入三相460V) | |||||||
| 输入功率(最大) | 12kVA | 12kVA | 12kVA | 12kVA | 12kVA | 12kVA | 12kVA | 12kVA | 
| 效率 | 86 ~ 95% 因型号而异(*1) | |||||||
| 功率因数 | 0.99 typ.(480V 输入) / 0.95 typ.(200 ~ 415V 输入) | |||||||
| 漏电流 | < 3.5 毫安 | |||||||
| 记忆与序列 | ||||||||
| 内存数 | 3套(前面板操作) | |||||||
| 最大步数 | 每个序列 500 步 | |||||||
| 最大序列号 | 16 | |||||||
| 步进时间可设定范围 | 0.001 秒 ~ 999999.999 秒 | |||||||
| 标准接口 | ||||||||
| 局域网接口 | 1 x LXI 1.4 用于通信, | |||||||
| J1(辅助控制) | 功能:互锁、外部输出开/关、关断、报警信号输出、输出电压下降信号 | |||||||
| 可选模拟编程接口 | ||||||||
| 状态输出(干接点) | CV 状态、CC 状态、CP 状态、CR 状态、ON/OFF 状态 | |||||||
| 电压控制 | 0V~5V或0V~10V范围内额定输出电压的0%~100% | |||||||
| 电压控制精度(*2) | +/-0.2% | |||||||
| 电流控制 | 0V~5V或0V~10V范围内额定输出电流的0%~100% | |||||||
| 电流控制精度(*2) | +/-0.2% | |||||||
| 功率控制 | 0V~5V或0V~10V范围内额定输出电流的0%~100% | |||||||
| 功率控制精度(*2) | +/-0.2% | |||||||
| 监控输出 | 0 ~ 5V 或 0 ~ 10V 输出用于监控 V/A/W | |||||||
| 监控精度 (*2) | +/-0.2% | |||||||
| 参考输出 | 0 ~ 5VDC 或 0 ~ 10VDC (max=5mA),可在 MENU 中选择。 | |||||||
| 可选的 RS-485 编程接口 | ||||||||
| 波特率 | 4800/9600/19200/38400/57600/115200 | |||||||
| 行结束符 | Cr , Lf , Cr+Lf 可选 | |||||||
| 可选的 GPIB 编程接口 | ||||||||
| IEEE 标准 488.2.1992 | ||||||||
| 尺寸和重量 | ||||||||
| 外壳(宽x高x深) | 440 x 129 x 660 毫米 | |||||||
| 总计(宽x高x深) | 482 x 132 x 765.1 毫米 | |||||||
| 重量(公斤) | 36.3 | 36.3 | 34.8 | 34.8 | 34.8 | 34.8 | 34.8 | 34.8 | 
| DSP80-360WR | DSP160-180WR | DSP250-120WR | DSP350-84WR | DSP500-60WR | DSP650-46WR | DSP1000-30WR | DSP1300-23WR | |
| *1) 以上数据测试环境:恒温后湿机内,温度0℃~50℃,80%RH,启动30分钟,以2%~100%旅游输出电压、1%~100%焊接输出电流, 回授证明点为输出端子,于输出端子测得之平均数据 | 
| *2)合理度项目于室温23℃±5℃测得 | 
| *3)纹波和噪声(rms 值)测量带宽高达 300 kHz | 
| *4)纹波和噪声(峰值)测量带宽高达 20 MHz | 
| *5)输出电压达到定值±1%时间(输出电压输出值的10%到90%,以搜索性负载连接,输出输出功率10%以上)(图1) | 
| *6)负载负载(1 ~ 100%),输入电压180 ~ 264VAC 或 342 ~ 460VAC | 
| *7) CV: 输入电压,电流变化幅度% ~ 90% CC: 输入电压,电压外景值10% ~ 90% CP: 输入电压,电压电压*电流变化值值 10% ~ 90% | 
| *8)输出响应上升时间:电压由电压值10%上升时间90%图需要时间 输出响应下降时间:电压由电压值90%下降至10%需要时间(2) | 
| *9) WR系列最高输出电压为DSP-WR系列最高输出电压为DSP-WR系列最高输出电压为DSP的105%,但总输出功率不可超过功率的102%,此规格电压线路证明为目的,不可考虑使用,且规格特性不在保证范围内。 | 
| *10) DSP-WR系列最大输出电流为电流的102%,但总输出功率不可比功率的102%,此超出规格的电流以线路证明为目的规格,不可考虑使用,且且特性特性不在保证范围内。 | 
| *11)电源供应器输出特性受线路影响等因素影响,多台系统的精确参数请与本公司联系。 | 
| *12) V1 x A1 ~ V2 x A2 间数值 V 及 A 乘积小于或等于最大功率数值,为宽范围功能可能实现的全部电压和电流组合。 | 
| *13) V1可设定最大电流值为A1,A2可设定最大电压值为V2,V1及A2不同时存在 | 
| *14) LXI介面反应时间:100/1000M网路连线,电脑直接连接至DSP-WR,封包发送完毕后,至DA开始动作时间间隔。 | 
| *15)因本公司不断更新产品,故规格若有变更,恕不另行通知,网页内容说明参考,具体规格依产品时书具体规定。 | 
| *16)擎宏电子保留迳行更动规范及其他产品信息的权利,并拥有对规范的最终能力,且不承担内容之错误或疏失。 | 
| 图1 | 图2 | 
|  | 
 | 